Export limit exceeded: 24707 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (24707 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-25002 2026-04-15 8.8 High
Command Injection in the diagnostics interface of the Bosch Network Synchronizer allows unauthorized users full access to the device.
CVE-2024-43688 2 Openbsd, Vixie 2 Openbsd, Cron 2026-04-15 7.3 High
cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-24899 2026-04-15 7.2 High
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in openEuler aops-zeus on Linux allows Command Injection. This vulnerability is associated with program files https://gitee.Com/openeuler/aops-zeus/blob/master/zeus/conf/constant.Py. This issue affects aops-zeus: from 1.2.0 through 1.4.0.
CVE-2025-42877 1 Sap 3 Content Server, Internet Communication Manager, Web Dispatcher 2026-04-15 7.5 High
SAP Web Dispatcher, Internet Communication Manager (ICM), and SAP Content Server allow an unauthenticated user to exploit logical errors that lead to a memory corruption vulnerability. This results in high impact on the availability with no impact on confidentiality or integrity of the application.
CVE-2024-24892 2026-04-15 8.1 High
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Privilege Management vulnerability in openEuler migration-tools on Linux allows Command Injection, Restful Privilege Elevation. This vulnerability is associated with program files https://gitee.Com/openeuler/migration-tools/blob/master/index.Py. This issue affects migration-tools: from 1.0.0 through 1.0.1.
CVE-2024-24890 2026-04-15 7.8 High
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in openEuler gala-gopher on Linux allows Command Injection. This vulnerability is associated with program files https://gitee.Com/openeuler/gala-gopher/blob/master/src/probes/extends/ebpf.Probe/src/ioprobe/ioprobe.C. This issue affects gala-gopher: through 1.0.2.
CVE-2025-41684 1 Weidmueller 3 Ie-sr-2tx-wl, Ie-sr-2tx-wl-4g-eu, Ie-sr-2tx-wl-4g-us-v 2026-04-15 8.8 High
An authenticated remote attacker can execute arbitrary commands with root privileges on affected devices due to lack of improper sanitizing of user input in the Main Web Interface (endpoint tls_iotgen_setting).
CVE-2025-41683 1 Weidmueller 3 Ie-sr-2tx-wl, Ie-sr-2tx-wl-4g-eu, Ie-sr-2tx-wl-4g-us-v 2026-04-15 8.8 High
An authenticated remote attacker can execute arbitrary commands with root privileges on affected devices due to lack of improper sanitizing of user input in the Main Web Interface (endpoint event_mail_test).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-45242 1 Engeniustech 1 Enh1350ext Firmware 2026-04-15 7.8 High
EnGenius ENH1350EXT A8J-ENH1350EXT devices through 3.9.3.2_c1.9.51 allow (blind) OS Command Injection via shell metacharacters to the Ping or Speed Test utility. During the time of initial setup, the device creates an open unsecured network whose admin panel is configured with the default credentials of admin/admin. An unauthorized attacker in proximity to the Wi-Fi network can exploit this window of time to execute arbitrary OS commands with root-level permissions.
CVE-2024-45251 1 Elsight 1 Halo Firmware 2026-04-15 9.8 Critical
Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-41663 2026-04-15 9.8 Critical
For u-link Management API an unauthenticated remote attacker in a man-in-the-middle position can inject arbitrary commands in responses returned by WWH servers, which are then executed with elevated privileges. To get into such a position, clients would need to use insecure proxy configurations.
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-45252 1 Elsight 1 Halo Firmware 2026-04-15 9.8 Critical
Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-45288 1 Freebsd 1 Freebsd 2026-04-15 8.4 High
A missing null-termination character in the last element of an nvlist array string can lead to writing outside the allocated buffer.
CVE-2025-41649 2026-04-15 7.5 High
An unauthenticated remote attacker can exploit insufficient input validation to write data beyond the bounds of a buffer, potentially leading to a denial-of-service condition for the devices.
CVE-2025-41238 1 Vmware 3 Esxi, Fusion, Workstation 2026-04-15 9.3 Critical
VMware ESXi, Workstation, and Fusion contain a heap-overflow vulnerability in the PVSCSI (Paravirtualized SCSI) controller that leads to an out of-bounds write. A malicious actor with local administrative privileges on a virtual machine may exploit this issue to execute code as the virtual machine's VMX process running on the host. On ESXi, the exploitation is contained within the VMX sandbox and exploitable only with configurations that are unsupported. On Workstation and Fusion, this may lead to code execution on the machine where Workstation or Fusion is installed.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).