Export limit exceeded: 24707 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (24707 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-43656 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43655 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43654 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-6507 | 1 Deeplake | 1 Deeplake | 2026-04-15 | 8.1 High |
| Command injection when ingesting a remote Kaggle dataset due to a lack of input sanitization in the ingest_kaggle() API | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43652 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | ||||
| CVE-2024-43650 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-43649 | 2026-04-15 | 8.8 High | ||
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | ||||
| CVE-2024-43648 | 2026-04-15 | 8.8 High | ||
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-43651 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). | ||||
| CVE-2024-42370 | 1 Litestar-org | 1 Litestar | 2026-04-15 | 8.3 High |
| Litestar is an Asynchronous Server Gateway Interface (ASGI) framework. In versions 2.10.0 and prior, Litestar's `docs-preview.yml` workflow is vulnerable to Environment Variable injection which may lead to secret exfiltration and repository manipulation. This issue grants a malicious actor the permission to write issues, read metadata, and write pull requests. In addition, the `DOCS_PREVIEW_DEPLOY_TOKEN` is exposed to the attacker. Commit 84d351e96aaa2a1338006d6e7221eded161f517b contains a fix for this issue. | ||||
| CVE-2024-42029 | 1 Xdg | 1 Desktop Portal Hyperland | 2026-04-15 | 6.3 Medium |
| xdg-desktop-portal-hyprland (aka an XDG Desktop Portal backend for Hyprland) before 1.3.3 allows OS command execution, e.g., because single quotes are not used when sending a list of app IDs and titles via the environment. | ||||
| CVE-2024-40895 | 2026-04-15 | 6.4 Medium | ||
| FFRI AMC versions 3.4.0 to 3.5.3 and some OEM products that implement/bundle FFRI AMC versions 3.4.0 to 3.5.3 allow a remote unauthenticated attacker to execute arbitrary OS commands when certain conditions are met in an environment where the notification program setting is enabled and the executable file path is set to a batch file (.bat) or command file (.cmd) extension. | ||||
| CVE-2024-40893 | 1 Firewalla | 1 Box Software | 2026-04-15 | 6.8 Medium |
| Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software versions before 1.979. A physically close attacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including networkConfig.Interface.Phy.Eth0.Extra.PingTestIP, networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes. | ||||
| CVE-2024-40641 | 1 Projectdiscovery | 1 Nuclei | 2026-04-15 | 7.4 High |
| Nuclei is a fast and customizable vulnerability scanner based on simple YAML based DSL. In affected versions it a way to execute code template without -code option and signature has been discovered. Some web applications inherit from Nuclei and allow users to edit and execute workflow files. In this case, users can execute arbitrary commands. (Although, as far as I know, most web applications use -t to execute). This issue has been addressed in version 3.3.0. Users are advised to upgrade. There are no known workarounds for this vulnerability. | ||||
| CVE-2024-39251 | 1 Thunderobot | 1 Control Center | 2026-04-15 | 10 Critical |
| An issue in the component ControlCenter.sys/ControlCenter64.sys of ThundeRobot Control Center v2.0.0.10 allows attackers to access sensitive information, execute arbitrary code, or escalate privileges via sending crafted IOCTL requests. | ||||
| CVE-2024-7695 | 2026-04-15 | 7.5 High | ||
| Multiple switches are affected by an out-of-bounds write vulnerability. This vulnerability is caused by insufficient input validation, which allows data to be written to memory outside the bounds of the buffer. Successful exploitation of this vulnerability could result in a denial-of-service attack. | ||||
| CVE-2024-38665 | 2026-04-15 | 8.4 High | ||
| Out-of-bounds write in some Intel(R) Graphics Drivers may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2024-7728 | 1 Cayintech | 3 Cms-se, Cms-se\(18.04\), Cms-se\(22.04\) | 2026-04-15 | 7.2 High |
| The specific CGI of the CAYIN Technology CMS does not properly validate user input, allowing a remote attacker with administrator privileges to inject OS commands into the specific parameter and execute them on the remote server. | ||||
| CVE-2024-37676 | 1 Htop | 1 Htop | 2026-04-15 | 8.4 High |
| An issue in htop-dev htop v.2.20 allows a local attacker to cause an out-of-bounds access in the Header_populateFromSettings function. | ||||