| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the argument Username/Password results in use of default credentials. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer. |
| eNet SMART HOME server 2.2.1 and 2.3.1 ships with default credentials (user:user, admin:admin) that remain active after installation and commissioning without enforcing a mandatory password change. Unauthenticated attackers can use these default credentials to gain administrative access to sensitive smart home configuration and control functions. |
| Default credentials set for local privileged user in Virtual Appliance. The following products are affected: Acronis Cyber Protect Cloud Agent (VMware) before build 36943, Acronis Cyber Protect 17 (VMware) before build 41186. |
| Tattile Smart+, Vega, and Basic device families firmware versions 1.181.5 and prior ship with default credentials that are not forced to be changed during installation or commissioning. An attacker who can reach the management interface can authenticate using the default credentials and gain administrative access, enabling unauthorized access to device configuration and data. |
| SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a default credentials vulnerability that allows remote attackers to obtain administrative access to the management interface. Attackers can authenticate using the hardcoded default credentials without password change enforcement to gain full administrative control of the device. |
| OpenMQ exposes a TCP-based management service (imqbrokerd) that by default requires
authentication. However, the product ships with a default administrative account (admin/
admin) and does not enforce a mandatory password change on first use. After the first
successful login, the server continues to accept the default password indefinitely without
warning or enforcement.
In real-world deployments, this service is often left enabled without changing the default
credentials. As a result, a remote attacker with access to the service port could authenticate
as an administrator and gain full control of the protocol’s administrative features. |
| Istio is an open platform to connect, manage, and secure microservices. Prior to 1.29.1, 1.28.5, and 1.27.8, a user of Istio is impacted if the JWKS resolver becomes unavailable or the fetch fails, exposing hardcoded defaults regardless of use of the RequestAuthentication resource. This vulnerability is fixed in 1.29.1, 1.28.5, and 1.27.8. |
| By default, the password for the Access Manager's web interface, is set to 'admin'. In the tested version changing the password was not enforced. |
| Default credentials vulnerability exists in SuprOS
product. If exploited, this could allow an authenticated
local attacker to use an admin account created during
product deployment. |
| Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA.
This issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.3-00; Hitachi Ops Center OVA: from 10.9.3-00 before 11.0.2-01. |
| Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF contains an authentication credentials leakage vulnerability.This issue affects Hitachi Ops Center Common Services: from 10.0.0-00 before 11.0.0-04; Hitachi Ops Center Analyzer viewpoint OVF: from 10.0.0-00 before 11.0.0-04. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
| Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password.
A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged. |
| Use of Default Credentials vulnerability in Maruti Suzuki SmartPlay on Linux (Infotainment Hub modules) allows attacker to try common or default usernames and passwords.The issue was detected on a 2022 Maruti Suzuki Brezza in India Market.
This issue affects SmartPlay: 66T0.05.50. |
| iMonitor EAM 9.6394 ships with default administrative credentials that are also displayed within the management client’s connection dialog. If the administrator does not change these defaults, a remote attacker can authenticate to the EAM server and gain full control over monitored agents and data. This enables reading highly sensitive telemetry (including keylogger output) and issuing arbitrary actions to all connected clients. |
| NetBird VPN when installed using vendor's provided script failed to remove or change default password of an admin account created by ZITADEL.
This issue affects instances installed using vendor's provided script. This issue may affect instances created with Docker if the default password was not changed nor the user was removed.
This issue has been fixed in version 0.57.0 |
| A vulnerability was found in Thinkware Car Dashcam F800 Pro up to 20250226. It has been declared as problematic. This vulnerability affects unknown code of the component Device Registration Handler. The manipulation leads to use of default credentials. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in IROAD Dash Cam X5 up to 20250203. It has been rated as problematic. This issue affects some unknown processing of the component SSID. The manipulation leads to use of default credentials. The attack needs to be initiated within the local network. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Control-M/Agents use a kdb or PKCS#12 keystore by default, and the default keystore password is well known and documented.
An attacker with read access to the keystore could access sensitive data using this password. |
| IO-1020 Micro ELD uses a default WIFI password that could allow an adjacent attacker to connect to the device.
|