Search Results (4846 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-54127 2026-04-15 N/A
This vulnerability exists in the TP-Link Archer C50 due to presence of terminal access on a serial interface without proper access control. An attacker with physical access could exploit this by accessing the UART shell on the vulnerable device. Successful exploitation of this vulnerability could allow the attacker to obtain Wi-Fi credentials of the targeted system.
CVE-2024-53979 1 Ibm 1 Zhmc 2026-04-15 8.3 High
ibm.ibm_zhmc is an Ansible collection for the IBM Z HMC. The Ansible collection "ibm.ibm_zhmc" writes password-like properties in clear text into its log file and into the output returned by some of its Ansible module in the following cases: 1. The 'boot_ftp_password' and 'ssc_master_pw' properties are passed as input to the zhmc_partition Ansible module. 2. The 'ssc_master_pw' and 'zaware_master_pw' properties are passed as input to the zhmc_lpar Ansible module. 3. The 'password' property is passed as input to the zhmc_user Ansible module (just in log file, not in module output). 4. The 'bind_password' property is passed as input to the zhmc_ldap_server_definition Ansible module. These properties appear in the module output only when they were specified in the module input and when creating or updating the corresponding resources. They do not appear in the output when retrieving facts for the corresponding resources. These properties appear in the log file only when the "log_file" module input parameter is used. By default, no log file is created. This issue has been fixed in ibm.ibm_zhmc version 1.9.3. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-53651 2026-04-15 4.6 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device.
CVE-2024-52284 1 Suse 1 Rancher 2026-04-15 7.7 High
Unauthorized disclosure of sensitive data: Any user with `GET` or `LIST` permissions on `BundleDeployment` resources could retrieve Helm values containing credentials or other secrets.
CVE-2024-41124 2026-04-15 6.3 Medium
Puncia is the Official CLI utility for Subdomain Center & Exploit Observer. `API_URLS` is utilizing HTTP instead of HTTPS for communication that can lead to issues like Eavesdropping, Data Tampering, Unauthorized Data Access & MITM Attacks. This issue has been addressed in release version 0.21 by using https rather than http connections. All users are advised to upgrade. There is no known workarounds for this vulnerability.
CVE-2024-40595 1 Oneidentity 1 Safeguard For Privileged Sessions 2026-04-15 5.3 Medium
An authentication-bypass issue in the RDP component of One Identity Safeguard for Privileged Sessions (SPS) On Premise before 7.5.1 (and LTS before 7.0.5.1) allows man-in-the-middle attackers to obtain access to privileged sessions on target resources by intercepting cleartext RDP protocol information.
CVE-2024-40594 2026-04-15 2.3 Low
The OpenAI ChatGPT app before 2024-07-05 for macOS opts out of the sandbox, and stores conversations in cleartext in a location accessible to other apps.
CVE-2024-40457 1 No-ip 1 Duc 2026-04-15 9.1 Critical
No-IP Dynamic Update Client (DUC) v3.x uses cleartext credentials that may occur on a command line or in a file. NOTE: the vendor's position is that cleartext in /etc/default/noip-duc is recommended and is the intentional behavior.
CVE-2024-3742 2026-04-15 7.5 High
Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.
CVE-2024-36119 1 Statamic 1 Cms 2026-04-15 1.8 Low
Statamic is a, Laravel + Git powered CMS designed for building websites. In affected versions users registering via the `user:register_form` tag will have their password confirmation stored in plain text in their user file. This only affects sites matching **all** of the following conditions: 1. Running Statamic versions between 5.3.0 and 5.6.1. (This version range represents only one calendar week), 2. Using the `user:register_form` tag. 3. Using file-based user accounts. (Does not affect users stored in a database.), 4. Has users that have registered during that time period. (Existing users are not affected.). Additionally passwords are only visible to users that have access to read user yaml files, typically developers of the application itself. This issue has been patched in version 5.6.2, however any users registered during that time period and using the affected version range will still have the the `password_confirmation` value in their yaml files. We recommend that affected users have their password reset. System administrators are advised to upgrade their deployments. There are no known workarounds for this vulnerability. Anyone who commits their files to a public git repo, may consider clearing the sensitive data from the git history as it is likely that passwords were uploaded.
CVE-2024-35495 2026-04-15 4.3 Medium
An Information Disclosure vulnerability in the Telemetry component in TP-Link Kasa KP125M V1.0.0 and Tapo P125M 1.0.0 Build 220930 Rel.143947 allows attackers to observe device state via observing network traffic.
CVE-2024-23942 2026-04-15 7.1 High
A local user may find a configuration file on the client workstation with unencrypted sensitive data. This allows an attacker to impersonate the device or prevent the device from accessing the cloud portal which leads to a DoS.
CVE-2024-23584 1 Hcltech 1 Bigfix Enterprise Suite Asset Discovery 2026-04-15 6.6 Medium
The NMAP Importer service​ may expose data store credentials to authorized users of the Windows Registry.
CVE-2024-1657 1 Redhat 3 Ansible Automation Platform, Ansible Automation Platform Developer, Ansible Automation Platform Inside 2026-04-15 8.1 High
A flaw was found in the ansible automation platform. An insecure WebSocket connection was being used in installation from the Ansible rulebook EDA server. An attacker that has access to any machine in the CIDR block could download all rulebook data from the WebSocket, resulting in loss of confidentiality and integrity of the system.
CVE-2024-12378 2026-04-15 9.1 Critical
On affected platforms running Arista EOS with secure Vxlan configured, restarting the Tunnelsec agent will result in packets being sent over the secure Vxlan tunnels in the clear.
CVE-2023-49341 2026-04-15 7.5 High
An issue was discovered in Newland Nquire 1000 Interactive Kiosk version NQ1000-II_G_V1.00.011, allows remote attackers to obtain sensitive information via cleartext credential storage in backup.htm component.
CVE-2025-59448 1 Yosmart 3 Yolink Hub, Yolink Mobile Application, Yolink Mqtt Broker 2026-04-15 4.7 Medium
Components of the YoSmart YoLink ecosystem through 2025-10-02 leverage unencrypted MQTT to communicate over the internet. An attacker with the ability to monitor network traffic could therefore obtain sensitive information or tamper with the traffic to control affected devices. This affects YoLink Hub 0382, YoLink Mobile Application 1.40.41, and YoLink MQTT Broker. NOTE: The vendor states that the vulnerability described (related to insecure transmission) only impacts the legacy mobile application logic, not the Hub hardware or firmware. The Hub functions solely as a pass-through (transparent gateway) for LoRa wireless data and does not inspect or process the application layer data.
CVE-2023-28912 2026-04-15 5.7 Medium
The MIB3 unit stores the synchronized phone contact book in clear-text, allowing an attacker with either code execution privilege on the system or physical access to the system to obtain vehicle owner's contact data. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources.
CVE-2025-9970 1 Abb 1 Mconfig 2026-04-15 7.4 High
Cleartext Storage of Sensitive Information in Memory vulnerability in ABB MConfig.This issue affects MConfig: through 1.4.9.21.
CVE-2025-8863 1 Yugabyte 1 Yugabytedb 2026-04-15 3.7 Low
YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission