Search Results (9099 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-11243 1 Shelly 1 Pro 4pm 2026-04-15 N/A
Allocation of Resources Without Limits or Throttling vulnerability in Shelly Pro 4PM (before v1.6) allows Excessive Allocation via network.
CVE-2025-11921 1 Bjango 1 Istats 2026-04-15 N/A
iStats contains an insecure XPC service that allows local, unprivileged users to escalate their privileges to root via command injection.This issue affects iStats: 7.10.4.
CVE-2025-1448 2026-04-15 7.3 High
A vulnerability was found in Synway SMG Gateway Management Software up to 20250204. It has been rated as critical. This issue affects some unknown processing of the file 9-12ping.php. The manipulation of the argument retry leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-14485 1 Iptime 1 A3004t 2026-04-15 5 Medium
A weakness has been identified in EFM ipTIME A3004T 14.19.0. This vulnerability affects the function show_debug_screen of the file /sess-bin/timepro.cgi of the component Administrator Password Handler. This manipulation of the argument aaksjdkfj with the input !@dnjsrureljrm*& causes command injection. The attack is possible to be carried out remotely. The complexity of an attack is rather high. It is stated that the exploitability is difficult. The exploit has been made available to the public and could be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-14525 1 Redhat 1 Container Native Virtualization 2026-04-15 6.4 Medium
A flaw was found in kubevirt. A user within a virtual machine (VM), if the guest agent is active, can exploit this by causing the agent to report an excessive number of network interfaces. This action can overwhelm the system's ability to store VM configuration updates, effectively blocking changes to the Virtual Machine Instance (VMI). This allows the VM user to restrict the VM administrator's ability to manage the VM, leading to a denial of service for administrative operations.
CVE-2025-4747 2026-04-15 6.3 Medium
A vulnerability was found in Bohua NetDragon Firewall 1.0 and classified as critical. This issue affects some unknown processing of the file /systemstatus/ip_status.php. The manipulation of the argument subnet leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-21090 1 Intel 3 Processors, Xeon, Xeon Processors 2026-04-15 6.5 Medium
Missing reference to active allocated resource for some Intel(R) Xeon(R) processors may allow an authenticated user to potentially enable denial of service via local access.
CVE-2025-23052 2026-04-15 7.2 High
Authenticated command injection vulnerability in the command line interface of a network management service. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands as a privileged user on the underlying operating system.
CVE-2025-23094 2026-04-15 7.3 High
The Platform component of Mitel OpenScape 4000 and OpenScape 4000 Manager V11 R0.22.0 through V11 R0.22.1, V10 R1.54.0 through V10 R1.54.1, and V10 R1.42.6 and earlier could allow an unauthenticated attacker to conduct a command injection attack due to insufficient parameter sanitization. A successful exploit could allow an attacker to execute arbitrary commands within the same privilege level as the web access process.
CVE-2025-23119 2026-04-15 N/A
An Improper Neutralization of Escape Sequences vulnerability could allow an Authentication Bypass with a Remote Code Execution (RCE) by a malicious actor with access to UniFi Protect Cameras adjacent network.
CVE-2025-24285 2026-04-15 9.8 Critical
Multiple Improper Input Validation vulnerabilities in UniFi Connect EV Station Lite may allow a Command Injection by a malicious actor with network access to the UniFi Connect EV Station Lite. Affected Products: UniFi Connect EV Station Lite (Version 1.5.1 and earlier) Mitigation: Update UniFi Connect EV Station Lite to Version 1.5.2 or later
CVE-2025-24293 1 Rails 1 Activestorage 2026-04-15 8.1 High
# Active Storage allowed transformation methods potentially unsafe Active Storage attempts to prevent the use of potentially unsafe image transformation methods and parameters by default. The default allowed list contains three methods allow for the circumvention of the safe defaults which enables potential command injection vulnerabilities in cases where arbitrary user supplied input is accepted as valid transformation methods or parameters. Impact ------ This vulnerability impacts applications that use Active Storage with the image_processing processing gem in addition to mini_magick as the image processor. Vulnerable code will look something similar to this: ``` <%= image_tag blob.variant(params[:t] => params[:v]) %> ``` Where the transformation method or its arguments are untrusted arbitrary input. All users running an affected release should either upgrade or use one of the workarounds immediately. Workarounds ----------- Consuming user supplied input for image transformation methods or their parameters is unsupported behavior and should be considered dangerous. Strict validation of user supplied methods and parameters should be performed as well as having a strong [ImageMagick security policy](https://imagemagick.org/script/security-policy.php) deployed. Credits ------- Thank you [lio346](https://hackerone.com/lio346) for reporting this!
CVE-2025-47188 2026-04-15 6.5 Medium
A vulnerability in the Mitel 6800 Series, 6900 Series, and 6900w Series SIP Phones through 6.4 SP4 (R6.4.0.4006), and the 6970 Conference Unit through 6.4 SP4 (R6.4.0.4006) or version V1 R0.1.0, could allow an unauthenticated attacker to conduct a command injection attack due to insufficient parameter sanitization. A successful exploit could allow an attacker to execute arbitrary commands within the context of the phone, leading to disclosure or modification of sensitive configuration data or affecting device availability and operation.
CVE-2025-24317 2026-04-15 N/A
Allocation of resources without limits or throttling issue exists in HMI ViewJet C-more series and HMI GC-A2 series, which may allow a remote unauthenticated attacker to cause a denial-of-service (DoS) condition.
CVE-2025-24333 2026-04-15 6.4 Medium
Nokia Single RAN baseband software earlier than 24R1-SR 1.0 MP contains administrative shell input validation fault, which authenticated admin user can, in theory, potentially use for injecting arbitrary commands for unprivileged baseband OAM service process execution via special characters added to baseband internal COMA_config.xml file. This issue has been corrected starting from release 24R1-SR 1.0 MP and later, by adding proper input validation to OAM service process which prevents injecting special characters via baseband internal COMA_config.xml file.
CVE-2025-24341 2026-04-15 6.5 Medium
A vulnerability in the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to induce a Denial-of-Service (DoS) condition on the device via multiple crafted HTTP requests. In the worst case, a full power cycle is needed to regain control of the device.
CVE-2025-27144 1 Redhat 10 Advanced Cluster Security, Enterprise Linux, Logging and 7 more 2026-04-15 7.5 High
Go JOSE provides an implementation of the Javascript Object Signing and Encryption set of standards in Go, including support for JSON Web Encryption (JWE), JSON Web Signature (JWS), and JSON Web Token (JWT) standards. In versions on the 4.x branch prior to version 4.0.5, when parsing compact JWS or JWE input, Go JOSE could use excessive memory. The code used strings.Split(token, ".") to split JWT tokens, which is vulnerable to excessive memory consumption when processing maliciously crafted tokens with a large number of `.` characters. An attacker could exploit this by sending numerous malformed tokens, leading to memory exhaustion and a Denial of Service. Version 4.0.5 fixes this issue. As a workaround, applications could pre-validate that payloads passed to Go JOSE do not contain an excessive number of `.` characters.
CVE-2025-27211 1 Ui 1 Edgeswitch 2026-04-15 7.5 High
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
CVE-2025-27212 2 Ubiquiti, Ui 5 Unifi Access Points, Unifi Os, Intercom and 2 more 2026-04-15 9.8 Critical
An Improper Input Validation in certain UniFi Access devices could allow a Command Injection by a malicious actor with access to UniFi Access management network. Affected Products: UniFi Access Reader Pro (Version 2.14.21 and earlier) UniFi Access G2 Reader Pro (Version 1.10.32 and earlier) UniFi Access G3 Reader Pro (Version 1.10.30 and earlier) UniFi Access Intercom (Version 1.7.28 and earlier) UniFi Access G3 Intercom (Version 1.7.29 and earlier) UniFi Access Intercom Viewer (Version 1.3.20 and earlier) Mitigation: Update UniFi Access Reader Pro Version 2.15.9 or later Update UniFi Access G2 Reader Pro Version 1.11.23 or later Update UniFi Access G3 Reader Pro Version 1.11.22 or later Update UniFi Access Intercom Version 1.8.22 or later Update UniFi Access G3 Intercom Version 1.8.22 or later Update UniFi Access Intercom Viewer Version 1.4.39 or later
CVE-2025-27233 2 Microsoft, Zabbix 4 Windows, Zabbix, Zabbix-agent and 1 more 2026-04-15 N/A
Zabbix Agent 2 smartctl plugin does not properly sanitize smart.disk.get parameters, allowing an attacker to inject unexpected arguments into the smartctl command. This can be used to leak the NTLMv2 hash from a Windows system.