| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Use of fixed learning codes, one code to lock the car and the other code to unlock it, the Key Fob Transmitter in KIA-branded Aftermarket Generic Smart Keyless Entry System, primarily distributed in Ecuador, which allows a replay attack.
Manufacture is unknown at the time of release. CVE Record will be updated once this is clarified. |
| A vulnerability was found in Tenda TDSEE App up to 1.7.12. It has been declared as problematic. Affected by this vulnerability is an unknown functionality of the file /app/ConfirmSmsCode of the component Password Reset Confirmation Code Handler. The manipulation leads to improper restriction of excessive authentication attempts. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 1.7.15 is able to address this issue. It is recommended to upgrade the affected component. |
| Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow
management operations on the device such as firmware upgrades and device
reboot requiring an authentication. A wrong management of login
failures of the service allows a denial-of-service attack, leaving the telnet service
into an unreachable state. |
| Trilium Notes is an open-source, cross-platform hierarchical note taking application with focus on building large personal knowledge bases. In versions below 0.97.0, a brute-force protection bypass in the initial sync seed retrieval endpoint allows unauthenticated attackers to guess the login password without triggering rate limiting. Trilium is a single-user app without a username requirement, and brute-force protection bypass makes exploitation much more feasible. Multiple features provided by Trilium (e.g. MFA, share notes, custom request handler) indicate that Trilium can be exposed to the internet. This is fixed in version 0.97.0. |
| Authelia is an open-source authentication and authorization server providing two-factor authentication and single sign-on (SSO) for applications via a web portal. If users are allowed to sign in via both username and email the regulation system treats these as separate login events. This leads to the regulation limitations being effectively doubled assuming an attacker using brute-force to find a user password. It's important to note that due to the effective operation of regulation where no user-facing sign of their regulation ban being visible either via timing or via API responses, it's effectively impossible to determine if a failure occurs due to a bad username password combination, or a effective ban blocking the attempt which heavily mitigates any form of brute-force. This occurs because the records and counting process for this system uses the method utilized for sign in rather than the effective username attribute. This has a minimal impact on account security, this impact is increased naturally in scenarios when there is no two-factor authentication required and weak passwords are used. This makes it a bit easier to brute-force a password. A patch for this issue has been applied to versions 4.38.19, and 4.39.0. Users are advised to upgrade. Users unable to upgrade should 1. Not heavily modify the default settings in a way that ends up with shorter or less frequent regulation bans. The default settings effectively mitigate any potential for this issue to be exploited. and 2. Disable the ability for users to login via an email address. |
| An issue was discovered in Bravura Security Fabric versions 12.3.x before 12.3.5.32784, 12.4.x before 12.4.3.35110, 12.5.x before 12.5.2.35950, 12.6.x before 12.6.2.37183, and 12.7.x before 12.7.1.38241. An unauthenticated attacker can cause a resource leak by issuing multiple failed login attempts through API SOAP. |
| An issue in the BYD Dilink Headunit System v3.0 to v4.0 allows attackers to bypass authentication via a bruteforce attack. |
| Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device. |
| A vulnerability has been found in Harness 3.3.0. Affected is an unknown function of the file /api/v1/login of the component Login Endpoint. The manipulation leads to improper restriction of excessive authentication attempts. Remote exploitation of the attack is possible. The attack is considered to have high complexity. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Unexpected authentication form rendering in HTML Form Adapter using only non-default redirectless mode in PingFederate allows authentication attempts which may enable brute force login attacks. |
| Lack of protection against brute force attacks in Valmet DNA visualization in DNA Operate. The possibility to make an arbitrary number of login attempts without any rate limit gives an attacker an increased chance of guessing passwords and then performing switching operations. |
| A vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could
cause account takeover and unauthorized access to the system
when an attacker conducts brute-force attacks against the
equipment login. Note that the system supports only one concurrent session and implements a delay of more than a second
between failed login attempts making it difficult to automate the
attacks. |
| There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure. |
| A vulnerability was found in Windmill 1.380.0. It has been classified as problematic. Affected is an unknown function of the file backend/windmill-api/src/users.rs of the component HTTP Request Handler. The manipulation leads to improper restriction of excessive authentication attempts. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. Upgrading to version 1.390.1 is able to address this issue. The patch is identified as acfe7786152f036f2476f93ab5536571514fa9e3. It is recommended to upgrade the affected component. |
| An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. |
| An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept second (or subsequent) broadcast fragments even when sent in plaintext and process them as full unfragmented frames. An adversary can abuse this to inject arbitrary network packets independent of the network configuration. |
| JetKVM before 0.5.4 does not rate limit login requests, enabling brute-force attempts to guess credentials. |
| MinIO is a high-performance object storage system. Prior to RELEASE.2026-03-17T21-25-16Z, MinIO AIStor's STS (Security Token Service) AssumeRoleWithLDAPIdentity endpoint is vulnerable to LDAP credential brute-forcing due to two combined weaknesses: (1) distinguishable error responses that enable username enumeration, and (2) absence of rate limiting on authentication attempts. An unauthenticated network attacker can enumerate valid LDAP usernames and then perform unlimited password guessing to obtain temporary AWS-style STS credentials, gaining access to the victim's S3 buckets and objects. This issue has been patched in RELEASE.2026-03-17T21-25-16Z. |
| Federated Learning and Interoperability Platform (FLIP) is an open-source platform for federated training and evaluation of medical imaging AI models across healthcare institutions. The FLIP login page in versions 0.1.1 and prior has no rate limiting or CAPTCHA, enabling brute-force and credential-stuffing attacks. FLIP users are external to the organization, increasing credential reuse risk. As of time of publication, it is unclear if a patch is available. |
| OpenClaw before 2026.3.12 applies rate limiting only after successful webhook authentication, allowing attackers to bypass rate limits and brute-force webhook secrets. Attackers can submit repeated authentication requests with invalid secrets without triggering rate limit responses, enabling systematic secret guessing and subsequent forged webhook submission. |