Search Results (4013 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-3219 1 Python Software Foundation 1 Cpython 2026-04-15 N/A
The “socket” module provides a pure-Python fallback to the socket.socketpair() function for platforms that don’t support AF_UNIX, such as Windows. This pure-Python implementation uses AF_INET or AF_INET6 to create a local connected pair of sockets. The connection between the two sockets was not verified before passing the two sockets back to the user, which leaves the server socket vulnerable to a connection race from a malicious local peer. Platforms that support AF_UNIX such as Linux and macOS are not affected by this vulnerability. Versions prior to CPython 3.5 are not affected due to the vulnerable API not being included.
CVE-2024-31218 2026-04-15 9.8 Critical
Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network.
CVE-2024-2104 1 Jbl 2 Live Pro 2 Tws, Tune Flex 2026-04-15 8.8 High
Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable.
CVE-2024-12757 2026-04-15 8.6 High
Nedap Librix Ecoreader is missing authentication for critical functions that could allow an unauthenticated attacker to potentially execute malicious code.
CVE-2024-12371 2026-04-15 N/A
A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.
CVE-2024-11980 1 Billion Electric 3 M120n, M150, M500 2026-04-15 8.6 High
Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device.
CVE-2024-10776 1 Sick 2 Inspector61x Firmware, Inspector62x Firmware 2026-04-15 8.2 High
Lua apps can be deployed, removed, started, reloaded or stopped without authorization via AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write files or load apps that use all features of the product available to a customer.
CVE-2024-10774 1 Sick 2 Inspector61x Firmware, Inspector62x Firmware 2026-04-15 7.3 High
Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication.
CVE-2025-41090 1 Ccn-cert 1 Microclaudia 2026-04-15 N/A
microCLAUDIA in v3.2.0 and prior has an improper access control vulnerability. This flaw allows an authenticated user to perform unauthorized actions on other organizations' systems by sending direct API requests. To do so, the attacker can use organization identifiers obtained through a compromised endpoint or deduced manually. This vulnerability allows access between tenants, enabling an attacker to list and manage remote assets, uninstall agents, and even delete vaccines configurations.
CVE-2025-46275 2026-04-15 9.8 Critical
WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could allow an attacker to create an administrator account without knowing any existing credentials.
CVE-2021-47709 1 Commax 1 Smart Home System 2026-04-15 N/A
COMMAX Smart Home System allows an unauthenticated attacker to change configuration and cause denial-of-service through the setconf endpoint. Attackers can trigger a denial-of-service scenario by sending a malformed request to the setconf endpoint.
CVE-2023-41918 2026-04-15 10 Critical
A vulnerability allows unauthorized access to functionality inadequately constrained by ACLs. Attackers may exploit this to unauthenticated execute commands potentially leading to unauthorized data manipulation, access to privileged functions, or even the execution of arbitrary code.
CVE-2021-4461 1 Seeyon 1 Zhiyuan Oa Web Application System 2026-04-15 N/A
Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC.
CVE-2021-4468 1 Planex 2 Cs-qp50f, Cs-qp50f-ing2 2026-04-15 N/A
PLANEX CS-QP50F-ING2 smart cameras expose a configuration backup interface over HTTP that does not require authentication. A remote, unauthenticated attacker can directly retrieve a compressed configuration backup file from the device. The backup contains sensitive configuration information, including credentials, allowing an attacker to obtain administrative access to the camera and compromise the confidentiality of the monitored environment.
CVE-2021-4469 1 Denver 2 I, Sho-110 2026-04-15 N/A
Denver SHO-110 IP cameras expose a secondary HTTP service on TCP port 8001 that provides access to a '/snapshot' endpoint without authentication. While the primary web interface on port 80 enforces authentication, the backdoor service allows any remote attacker to retrieve image snapshots by directly requesting the 'snapshot' endpoint. An attacker can repeatedly collect snapshots and reconstruct the camera stream, compromising the confidentiality of the monitored environment.
CVE-2021-47710 1 Commax 1 Smart Home System 2026-04-15 N/A
COMMAX Smart Home System is a smart IoT home solution that allows an unauthenticated attacker to disclose RTSP credentials in plain-text by exploiting the /overview.asp endpoint. Attackers can access sensitive information, including login credentials and DVR settings, by submitting a GET request to this endpoint.
CVE-2021-47891 2 Unified Intents, Unifiedremote 2 Unified Remote, Unified Remote 2026-04-15 9.8 Critical
Unified Remote 3.9.0.2463 contains a remote code execution vulnerability that allows attackers to send crafted network packets to execute arbitrary commands. Attackers can exploit the service by connecting to port 9512 and sending specially crafted packets to open a command prompt and download and execute malicious payloads.
CVE-2023-22650 1 Suse 1 Rancher 2026-04-15 8.8 High
A vulnerability has been identified in which Rancher does not automatically clean up a user which has been deleted from the configured authentication provider (AP). This characteristic also applies to disabled or revoked users, Rancher will not reflect these modifications which may leave the user’s tokens still usable.
CVE-2022-43110 1 Voltronicpower 1 Viewpower 2026-04-15 9.8 Critical
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
CVE-2024-23943 2026-04-15 9.1 Critical
An unauthenticated remote attacker can gain access to the cloud API due to a lack of authentication for a critical function in the affected devices. Availability is not affected.